微 信 题 库 搜 索
医学英语
图谱资源
英语教学 医学词汇 中医英语 临床英语
多媒体 药学英语 护理英语 动态资讯
 医学全在线 > 医学英语 > 临床英语 > 临床英语 > 正文
呼吸暂停监护仪
来源:医学全在线 更新:2008/10/7 字体:
Apnea Monitor
呼吸暂停监护仪
Equipment
用品
1. Apnea monitor with electrodes
电极窒息监护仪。
2. Material to cleanse the infant’s skin
婴儿皮肤清洁用品。
Implementation
实施
1. Wash hands.
1、洗手。
2. Gather equipment.
2、收集器械
3. Explain to caregivers what is to be done and why.
3、向护理员说明操作程序及目的。
4. Prepare the infant’s skin by making sure it is clean and dry.
4、婴儿皮肤准备,确保皮肤清洁干燥。
5. Apply the electrodes (either to the infant or to the electrode belt, depending on the type of monitor being used).
5、贴电极片(根据监护仪类型,将电极贴于婴儿皮肤或贴于电极带)。
6. Place the electrode belt at the infant’s nipple line.
6、将电极带置于婴儿乳头线边上。
7. Skin electrodes are usually best placed between the infant’s nipple and armpit and may be repositioned somewhere else.
7、皮肤电极通常置于婴儿乳头和腋窝之间,也可以置于其他部位。
8. Insert lead wires. Insert the white lead wire on the right side. Insert the black wire on the left.医.学.全.在.线.网.站.提供
8、插入导联线:白色导联线插右侧;黑色导联线插入左侧。
9. Insert the corresponding lead wire into the cable, and insert the cable into the monitor. The cable is usually color coded to match the lead wires.
9、将相应导联线与电线相接,将电线插入监护仪。电线颜色通常与导联线颜色相配。
10. Attach the belt to the infant. The belt should be snug but you should be able to insert two fingers under it.
10、电极带固定于婴儿身上。电极带固定松紧度以能插入两个手指为宜。
11. Make sure the monitor is plugged in, the cable is attached, and the alarms are properly set.
11、确保监护仪、电线和报警装置连接设置正常。
12. Turn on the monitor. The indicator lights should be on as well.
12、打开监护仪。指示灯亮。
13. Settle the infant comfortably, or allow caregivers to hold and comfort their infant.
13、舒适地安置婴儿,或由护理员怀抱并安慰婴儿。
14. If the monitor alarm sounds:
14、监护仪报警时:
Check the infant immediately.
Check the infant’s breathing and color. If the infant is pink but not breathing, wait until the 10th beep before starting stimulation. If the infant is not pink, begin stimulation immediately. Believe observations of the infant before relying on the monitor.
立即检查婴儿
检查婴儿呼吸和肤色。如肤色粉红但无呼吸,等警报器蜂鸣10下后再开始刺激。不是粉红色时,则立即开始刺激。操作时以观察结果为准,监护仪显示作参考
15. Use this stimulation sequence: Gently touch the infant; flick the infant’s heel; slap the infant’s foot; rub the infant’s back. (Note: Be certain to teach caregivers never to shake the infant). If the child does not respond, start cardiopulmonary resuscitation (CPR). After the problem resolves, the alarm will stop.
15、连续刺激:轻触婴儿,指弹婴儿脚跟,拍击婴儿足部,搓擦婴儿背部(教导护理员绝不能摇晃婴儿)。如无反应,开始心肺复苏。问题解决,告警停止。
16. Press the reset button to turn off the alarm indicator.
16、按复位键关闭告警指示器。
Record and report
记录与报告
1. Document and report any alarms and nursing responses.
1、记录并报告警报及护理反应。
2. Document the infant’s condition. Always note alarm settings when starting and ending any contact with the infant and at least every hour in between.
2、记录婴儿病情。在开始和结束与婴儿接触时应始终注意警报器设置,每小时不少于一次。
相关文章
The Relationship Between Qi And Blood
COPD (Chronic Obstructive Pulmonary Dis
中医常用词汇英文翻译03
定语移位在医学英语中的理解与应用
Chinese Herb:Haliotidis(石决明)
   触屏版       电脑版       全站搜索       网站导航   
版权所有:医学全在线(m.med126.com)
网站首页
频道导航
医学论坛
返回顶部
Baidu
map